On This Job
Freestanding stoves wear at the parts that touch the fire: rope gaskets go flat, baffle boards crack, firebrick breaks and stovepipe rusts at the seams. We replace each with parts for that stove, check the hearth pad and wall clearances against the stove's label, and look at the chimney connection. Repairs are priced in writing, and if a stove is past saving we tell you so.
Freestanding stoves and their labels
A wood stove carries a label on its back or side naming the maker, the model, the standard it was tested to, and the distances it needs from walls and from anything that burns. Those numbers decide what we can fix and how. A stove set closer to a wall than its label allows is a problem no gasket will solve; the fix is listed wall shielding or moving the stove. Inside, the parts that take the heat are made to be replaced: door and glass gaskets, firebrick, the baffle plate or tubes above the fire, the secondary air tubes in newer clean-burning models, and the catalytic combustor in stoves that have one. We order each by the model number. The stovepipe from the stove to the ceiling and the chimney above it are part of the same system, and on a factory-built chimney the pipe and its ceiling support carry a listing of their own.
Symptoms point to parts. A stove that runs hot and eats wood even with its air control closed has an air leak, most often a door gasket flattened by years of use or a cracked weld. A stove that puffs smoke into the room when the door opens may have a baffle that has slipped out of place, a dirty or blocked chimney, or a pipe run with too many turns. Glass that goes brown or black over one evening points to wet wood, low burn temperatures or a door letting cold air wash across the glass the wrong way. A catalytic stove that has stopped burning clean may need a new combustor. Once the part is in, we light a small fire and watch how the stove behaves before we leave. The price for parts and labor is given to you in writing on the visit, and nothing is replaced without your say-so.
Wood stoves in the valley today
Wood stoves in the San Gabriel Valley sit under South Coast AQMD Rule 445, which bans wood burning on days when air quality is poor and restricts new wood-burning devices in new construction. Existing stoves in existing houses can stay in use outside those no-burn days. That makes a working, clean-burning stove worth looking after. Many of the stoves we see in Glendora and Claremont are older units without a secondary air system, and those burn dirtier and put more creosote into the chimney. Keeping one sound means tight gaskets, an intact baffle, dry wood and a swept chimney. If the stove body is cracked, its door warped past adjusting, or its parts no longer made, we will say plainly that more repair money is hard to justify, and lay out the alternatives, gas included, with a price on each so you can compare them side by side.
A stove's chimney deserves as much attention as the stove. Most freestanding stoves in tract houses here vent through a factory-built chimney: connector pipe from the stove up to a support box at the ceiling, then listed chimney pipe through the attic and roof to a termination. Each joint, the support box, the attic shield and the roof flashing belong to that listing. A connector with screws missing, a support box packed with insulation, or a termination from a different maker are all things we correct as part of a stove repair, since a repaired stove vented through a faulty pipe is no safer than before. If the stove sits on a hearth pad, we check that the pad still covers the area the label asks for in front and to the sides. Describe the stove, what it is doing and how it vents on the contact form, and we will come with the likely parts.
How Tully Chimney Works Handles It
Plate Read First
Maker and model recorded before any part is chosen
Arrival Window
Agreed with you on the booking call
Price on Paper
Repairs priced in writing and held for your yes
Fit to Use?
You hear plainly whether to light it before we go
Towns with a wood stove repair page
Glendora, Azusa, Covina and Claremont each get a page on how the work goes there: the houses, the fireplaces in them, the weather and the ZIP codes.
CA
Wood Stove Repair in Glendora
80% of local homes predate 1980. Hand us a factory-built firebox and the data plate gets read before a single part is ordered; hand us a 1920s-1940s brick stack and mortar joints plus quake cracks get the scrutiny instead.
Open the town pageCA
Wood Stove Repair in Azusa
48% of homes here are detached. On any metal fireplace we write down make and model, then fit only what that listing names: glass doors, refractory panels, termination cap, chase top. Nothing improvised from masonry stock.
Open the town pageCA
Wood Stove Repair in Covina
76% of homes predate 1980. Plenty of 1950s-1960s brick or block chimneys took gas logs later. A firebox swapped for a factory-built unit counts as a separate listed appliance to us, needing its own flue, cap and clearances.
Open the town pageCA
Wood Stove Repair in Claremont
Old Village homes span the 1890s-1930s; ranch tracts came north of Foothill Boulevard during the 1950s-1970s. With a metal flue inside a framed chase, chase top, storm collar and listed cap are inspected together, as one assembly.
Open the town pageMore Services
Chimney Sweep
Flue and firebox brushed with heads that will not score a metal chimney, plus a parts check on the way out.
Read about it →Chimney Inspection
A Level 1 look at the firebox, panels, pipe joints and top, with the listing plate read and recorded.
Read about it →Chimney Repair
Repairs to metal pipe, chase tops, caps and brick stacks, each priced in writing before a tool comes out.
Read about it →Fireplace Inspection
The firebox, panels, screen, doors and gas or wood parts of a prefab unit, checked against its maker's listing.
Read about it →Fireplace Repair
Prefab fireboxes repaired with the panels, grates, doors and parts the maker lists for that model number.
Read about it →Chimney Level 2 Inspection
Video of every pipe joint from firebox to cap, plus the attic and chase, for a sale or after a quake.
Read about it →Chimney Cap Installation
Termination caps matched to the pipe brand on metal chimneys, or a mesh cap fixed to a brick flue.
Read about it →Chimney Flashing Repair
Water stopped where a brick stack or a framed chase meets the roof, with the leak point shown in photos.
Read about it →Chimney Masonry Repair
Mortar joints, broken brick and cracked crowns on the brick stacks that older houses still carry.
Read about it →Chimney Rebuilds
Brick stacks rebuilt above the roof, or replaced with a framed chase around a listed metal chimney.
Read about it →Fireplace Cleaning
Soot, ash and smoke film cleared from a metal firebox, its panels, its glass doors and its screen.
Read about it →Gas Fireplace Cleaning
Burner, pilot, logs, glass and vent of a gas fireplace serviced to the maker's manual for that model.
Read about it →Gas Fireplace Repair
Pilots, thermocouples, valves, switches and remotes on gas fireplaces, tested in order and fixed with model parts.
Read about it →Fireplace Remodel
A new surround, mantel or face around a prefab unit, kept inside the clearances on its listing.
Read about it →Fireplace Inserts
Gas inserts approved for a factory-built firebox or a brick fireplace, fitted with a vent of their own.
Read about it →Pellet Stove Repair
Pellet stoves that will not light, run lean or keep shutting down, traced to the failed part and fixed.
Read about it →Gas Logs
Log sets for wood-burning prefab units whose manual allows them, with the gas line run and tested.
Read about it →Chimney Seismic Retrofit
Brick stacks braced, strapped, or cut down and topped with a lighter framed chase, each option priced in writing.
Read about it →Chimney Crown Repair
Cracked mortar crowns on brick stacks sealed or recast; on a framed chase, the steel top does that job instead.
Read about it →Dryer Vent Cleaning
Lint cleared from the dryer duct between the machine and the outside hood, with the hood flap checked.
Read about it →Chimney Liner Installation
Stainless liners for brick flues and for inserts, sized from the appliance's vent rating and the flue's inside measure.
Read about it →Chimney Leak Repair
Water coming in at a chimney or chase traced to its entry point, then stopped and photographed.
Read about it →Chimney Waterproofing
A breathable water repellent on brick, applied after joints and crown are fixed, never in place of them.
Read about it →Chimney Damper Repair
Prefab damper blades, handles and linkages fixed with the maker's kit; brick fireplaces get throat or top dampers.
Read about it →Chimney Chase Cover
Rusted or pooling chase tops replaced in heavier stainless or galvanized steel, cut to the chase and the pipe.
Read about it →